Availability:
     Online     , CTRL-B

  Quick Help:
     Get Thermistor Temperature

  Description:
    This command get the thermistor temperature of the drive.

  Input Parameters:
    None

  Output Data:


    If an error occurred, the following information will be displayed.
    
          "DiagError aaaaaaaa"
    
       where
    
          aaaaaaaa is the Diagnostic Error Code
    
    If no error occurred and the Channel temperature was returned, the following message
    will be displayed.
    
          "Channel temp cccc, CCd"
    
       where
    
          cccc is the temperature value obtained from channel (hexadecimal)
            CC is the temperature value obtained from channel (decimal)
    
    If no error occurred and the Preamp temperature was returned, the following message
    will be displayed.
    
          "Preamp temp cccc, CCd"
    
       where
    
          cccc is the temperature value obtained from preamp (hexadecimal)
            CC is the temperature value obtained from preamp (decimal)
    
    If no error occurred and the Thermistor temperature was returned, the following
    message will be displayed.
    
          "Ref voltage dddd Thermistor voltage eeee Thermistor temp in degrees C ffff, FFd"
    
       where
    
          dddd is the A to D Reference Voltage
    
          eeee is the Thermistor Voltage
    
          ffff is the Thermistor Temperature in degrees Celsius (hexadecimal)
            FF is the Thermistor Temperature in degrees Celsius (decimal)
    
  Revision History:

    0001.0000   Initial revision.
    0011.0000   Combined the PSG Diagnostic Error Codes (PSGDEC) and the Diagnostic External
                Test Service Error Codes (DETSEC) into a single set of Diagnostic Error Codes
                (DiagError).
    0012.0000   Added Temperature in degrees Celsius (decimal) to output.