Availability:
     Online     , '>'

  Quick Help:
     Increment Read/Write Scope Sync

  Description:
    This command increments the number of the Servo Wedge for which the Scope Sync Pulse
    will be generated.

  Input Parameters:
    None

  Output Data:


    If an error occurred, the following information will be displayed.
    
          "DiagError aaaaaaaa"
    
       where
    
          aaaaaaaa is the Diagnostic Error Code
    
    If no error occurred, the following information will be displayed.
    
          "                  Burst cccc"
    
       where
    
          cccc is the current Scope Sync Wedge number
    
  Revision History:

    0001.0000   Initial revision.
    0011.0000   Combined the PSG Diagnostic Error Codes (PSGDEC) and the Diagnostic External
                Test Service Error Codes (DETSEC) into a single set of Diagnostic Error Codes