Availability:
     Online     , '!'

  Quick Help:
     Display Current Read Channel Settings

  Description:
    This command displays the current value of the Read Channel, Preamp and Power ASIC
    registers.

  Input Parameters:
    None

  Output Data:

    If a single Read Channel register was read, the following information will be displayed.
    
          "Read Channel Reg cccc = dddd"
    
       where
    
          cccc is the address of the register that was read
    
          dddd is the value that was read from the register
    
    If multiple Read Channel registers were read, the following information will be
    displayed.
    
          "Read Channel"
          "      0    1    2    3    4    5    6    7    8    A    B    C    D    E    F"
          "cccc: dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd"
    
       where
    
          cccc is the address of the first register in the row
    
          dddd is the value that was read from the register
    

    If a single Preamp register was read, the following information will be displayed.
    
          "Preamp Reg cc = dd"
    
       where
    
          cc is the address of the register that was read
    
          dd is the value that was read from the register
    
    If multiple Preamp registers were read, the following information will be displayed.
    
          "Preamp"
          "    0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F"
          "cc: dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd"
    
       where
    
          cc is the address of the first register in the row
    
          dd is the value that was read from the register
    

    If a single Power ASIC register was read, the following information will be displayed.
    
          "Power ASIC Reg cc = dddd"
    
       where
    
          cc is the address of the register that was read
    
          dddd is the value that was read from the register
    
    If multiple Power ASIC registers were read, the following information will be displayed.
    
          "Power ASIC"
          "    0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F"
          "cc: dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd dddd"
    
       where
    
          cc is the address of the first register in the row
    
          dddd is the value that was read from the register
    
  Revision History:

    0001.0000   Initial revision.
    0011.0000   Combined the PSG Diagnostic Error Codes (PSGDEC) and the Diagnostic External
                Test Service Error Codes (DETSEC) into a single set of Diagnostic Error Codes
                (DiagError).