Availability:
     Level A    , 'P'

  Quick Help:
     Merge Alt List into Slip List, P

  Description:
    The Merge Alt List Into Slip List command merges all defects from the G list into the
    P list and then regenerates the alt and slip lists.  This in effect changes alternated
    sectors to slipped sectors.

  Input Parameters:
    None

  Output Data:

    The Merge Alt List Into Slip List output information will be displayed as follows.
    
    For all error cases, the following message will be displayed.
    
          "Command may take 10's of seconds, be patient..."

    If an error occurred, the following information will be displayed.
    
          "DiagError aaaaaaaa"
    
       where
    
          aaaaaaaa is the Diagnostic Error Code
    
    If an error occurred, the following information will also be displayed.
    
          "R/W Status c R/W Error dddddddd"
    
       where
    
          c is the status returned by the R/W subsystem
    
                0 = R/W request completed successfully with error recovery
                1 = R/W request completed successfully (no error recovery performed)
                2 = R/W request failed
    
          dddddddd is the error code returned by the R/W subsystem
    
    If no error occurred, then the following message will be displayed.
    
          "Command may take 10's of seconds, be patient...done."
    
    Note that the word "done" will be displayed upon completion of the command, which may
    require 10's of seconds.
    
  Revision History:

    0001.0000   Initial revision.
    0011.0000   Combined the PSG Diagnostic Error Codes (PSGDEC) and the Diagnostic External
                Test Service Error Codes (DETSEC) into a single set of Diagnostic Error Codes
                (DiagError).
    0012.0000   Added reporting of R/W error code if command fails.