Availability:
     Level 2    , 'I'
     Level 7    , 'I'

  Quick Help:
     Display / Modify Adaptive Parameter, I,[GroupId]

  Description:
    This command is used to invoke the Display / Modify Adaptive Parameter subcommands.

  Input Parameters:

    0 - Not Used.
    
        Please see the other Display / Modify Adaptive Parameters commands for details
        regarding the use of this parameter.
    
          Type:    N/A
    
          Range:   N/A
    
          Default: None
    
    1 - Adaptive Parameter Group ID (P1).
    
        This parameter specifies the ID of the Adaptive Parameter Group that contains
        the value to be displayed or modified.
    

          
          01 = RAP (Read / Write Adaptive Parameters)
          02 = SAP (Servo Adaptive Parameters)
          03 = RW Working Parameters (Read / Write Working Parameters)
          FF = Table of Contents (All allowable Group IDs)
          
          Type:    Unsigned 32-bit value
    
          Range:   0 to 0xFFFFFFFF
    
          Default: 0
    
  Output Data:
    Please see each individual Display / Modify Adaptive Parameter subcommand for more
    details regarding its output data format.

  Examples:

    The following will present the Display/Modify Adaptives command's Table of Contents:

       F3 2>I,FF

  Revision History:

    0001.0000   Initial revision.
    0002.0000   Corrected Working Parameters display for Maintenance Heat.
    0002.0001   Added separate command and diagnostic files to handle the different adaptive
    0011.0000   Combined the PSG Diagnostic Error Codes (PSGDEC) and the Diagnostic External
                Test Service Error Codes (DETSEC) into a single set of Diagnostic Error Codes
                (DiagError).
                parameters.
    0011.0001   Added support for modifying/reading SAP Flex Bias Table and SAP Bias Hysteresis Table
    0011.0002   Moved Controller Adaptive Parameter support to the Level T 'J' command.
    0011.0003   Fixed problem accessing the RAP Tuned Head Zone Parameters for RAP 16. RAP 16 changed
                the way this table is layed out which affects how the table index is calculated.
    0012.0000   Modified the CPIT display to include channel register number.