Availability:
     Level 5    , 'E'

  Quick Help:
     Measure Disc Eccentricity

  Description:
    This command performs the Measure Disc Eccentricity operation.
    
  Input Parameters:
    None

  Output Data:


    If an error occurred, the following information will be displayed.
    
          "DiagError aaaaaaaa"
    
       where
    
          aaaaaaaa is the Diagnostic Error Code
    
    If no error occurred, then the following will be displayed for each supported head:
    
          Disc Eccentricity In Microinches
          Head     Magnitude   Real        Imag
             a     b.bbbbb     c.cccccc    d.dddddd
    
          where
    
             a is the head used for the measurement
    
             b.bbbbb is the magnitude in microinches complex eccentricity for the designated head
    
             c.ccccc is the real component in microinches of the complex eccentricity for the
             designated head
    
             d.ddddd is the imaginary component in microinches of the complex eccentricity for
             the designated head
    
  Examples:
 
    Example #1:
    To measure disc eccentricity on all heads:
       
       F3 5>E
 
  Revision History:

    0001.0000   Initial revision.