Availability:
     Level 5    , 'e'

  Quick Help:
     Enable / Disable Shock Sensor, e[Operation]

  Description:
    This command will enable or disable the shock sensor and get its current status.

  Input Parameters:

    
    0 - Operation.
    
        0x00: SHOCK_SENSOR_DISABLE - Indicates that the shock sensor should be disabled.
        0x01: SHOCK_SENSOR_ENABLE - Indicates that the shock sensor should be enabled.
        0x02: GET_SHOCK_SENSOR_CURRENT_STATUS - Indicates that the current status of shock sensor
        should be retrieved.
    
          Type:    Unsigned 8-bit value
    
          Range:   0..2
    
          Default: 2
    
  Output Data:


    If an error occurred, the following information will be displayed.
    
          "DiagError aaaaaaaa"
    
       where
    
          aaaaaaaa is the Diagnostic Error Code
    
    If no error occurred and the shock sensor is disabled, the following message will be displayed:
        
       "Shock Sensor Disabled"
        
    If no error occurred and the shock sensor is enabled, the following message will be displayed:
        
       "Shock Sensor Enabled"
    
  Examples:
    Example #1:
    To display the current status of the shock sensor:
 
       F3 5>e
 
    Example #2:
    To disable the shock sensor:
 
       F3 5>e0

  Revision History:

    0001.0000   Initial revision.