Availability:
     Level 4    , 'O'

  Quick Help:
     Display Micro Jog for Logical Cylinder and Head, O[LogCyl],[Hd],[Opts],[SysAreaOpt]

  Description:
    The Display Micro Jog Value for Logical CHS commmand seeks to the specified logical
    track, gets the track's micro jog value and displays it.  If no address is specified,
    this command will seek to the next logical track in the Test Space and display its
    micro jog value.

  Input Parameters:

    0 - Logical Cylinder Address.
    
        If Parameter 3 is entered, Parameter 0 is the address of the System Area logical
        cylinder for which the micro jog value is to be displayed.  If Parameter 3 is not
        entered, Parameter 0 is the address of the User Area logical cylinder for which the
        micro jog value is to be displayed.  If both Parameter 0 and 1 are not entered,
        the micro jog value will be displayed for the next logical track in the Test Space.
    
          Type:    Unsigned 32-bit value
    
          Range:   0 to 0xFFFFFFFF
    
          Default: None
    
    1 - Logical Head Address.
    
        This parameter is the address of the Logical Head for which the micro jog value
        is to be displayed.  If both Parameter 0 and 1 are not entered, the micro jog
        value will be displayed for the next logical track in the Test Space.
    
          Type:    Unsigned 8-bit value
    
          Range:   0 to 0xFF
    
          Default: None
    
    2 - Display Micro Jog options.
    
        This parameter is a bit-significant value that specifies various options for
        displaying the micro jog value.  The bits are defined as follows:
    
          bit 0: Disable Micro Jog Display
                   0 enables the micro jog value to be displayed
                   1 disables the micro jog value from being displayed
    
          Type:    Unsigned 16-bit value
    
          Range:   0 to 0xFFFF
    
          Default: 0 (Micro Jog Display enabled)
    
    3 - System Area Flag.
    
        If any value is entered then Parameter 0 specifies a System Area logical cylinder,
        else it specifies a User Area logical cylinder.
    
          Type:    Unsigned 16-bit value
    
          Range:   0 to 0xFFFF
    
          Default: None
    
  Output Data:


    If an error occurred, the following information will be displayed.
    
          "DiagError aaaaaaaa"
    
       where
    
          aaaaaaaa is the Diagnostic Error Code
    
    If no error occurred, the Microjog Data will be displayed as follows.
    
          "bbbbbb LBA cccccccc LLL CHS dddddd.e.ffff PLP CHS gggggg.h.iiii"
          "MR Offset = jjjj"
    
       where
    
          bbbbbb   is either "User" or "System"
    
          cccccccc is the Disk Logical Block Address
    
          dddddd   is the Logical Cylinder Address
    
          e        is the Logical Head Address
    
          ffff     is the Logical Sector Address
    
          gggggg   is the Physical Cylinder Address
    
          h        is the Logical Head Address
    
          iiii     is the Physical Sector Address
    
          jjjj     is the MR Offset value for the track
    
  Revision History:

    0001.0000   Initial revision.
    0011.0000   Combined the PSG Diagnostic Error Codes (PSGDEC) and the Diagnostic External
                Test Service Error Codes (DETSEC) into a single set of Diagnostic Error Codes
                (DiagError).