Availability:
     Level 2    , 'k'

  Quick Help:
     Set User Cylinder/Head/MiniZone Skew, k[CylSkew],[HeadSkew],[MiniZoneSkew]

  Description:
    This command is used to set the user cyl/head/minizone skew.

  Input Parameters:

    0 - User Cylinder Skew
    
        This input establishes the user cylinder skew.
    
          Type:    Unsigned 16-bit value
    
          Range:   0 to 0xFFFF
    
          Default: current drive user cylinder skew
    
    1 - Head Skew
    
        This input establishes the head skew.
    
          Type:    Unsigned 16-bit value
    
          Range:   0 to 0xFFFF
    
          Default: current drive head skew
    
    2 - MiniZone Skew
    
        This input establishes the minizone skew.
    
          Type:    Unsigned 16-bit value
    
          Range:   0 to 0xFFFF
    
          Default: current drive minzone skew
    
  Output Data:


    If an error occurred, the following information will be displayed.
    
          "DiagError aaaaaaaa"
    
       where
    
          aaaaaaaa is the Diagnostic Error Code
    
    If no error occurred, the following information will be displayed.
    
           Cyl Skew   Head Skew   MnZn Skew
       Old   AA          BB          CC
       New   DD          EE          FF
    
       where
    
          AA is the original user cylinder to cylinder skew in servo wedges
    
          BB is the original head to head skew in servo wedges
    
          CC is the original minizone to minizone skew in servo wedges
    
          DD is the new user cylinder to cylinder skew in servo wedges
    
          EE is the new head to head skew in servo wedges
    
          FF is the new minizone to minizone skew in servo wedges
    
  Examples:
 
    Example #1:
    To set user cylinder skew to 40, minizone skew to 50 and keep
    head skew unmodified:
 
       F3 2>k40,,50

  Revision History:

    0001.0000   Initial revision.